At whatever point it is chosen to build a dam, the principal question that one face is which sort of dam will be most reasonable and generally temperate? Following are the variables influencing determination of dam site by dam write.

Geography

Geography and Foundation Conditions

Accessibility of materials

Spillway size and area

Seismic tremor zone

Tallness of the Dam

Different factors, for example, cost of development and upkeep, life of dam, style and so on.

Components Affecting Selection of Dam

These elements are talked about one by one.

Geography 

Geography directs the primary decision of the sort of dam.

A limited U-formed valley, i.e. a limited stream streaming between high rough dividers, would propose a solid flood dam.

A low plain nation, would recommend an earth fill dam with discrete spillways.

A thin V-molded valley shows the decision of an Arch dam

Topographical and Foundation Conditions 

Topographical and Foundation conditions ought to be altogether studied in light of the fact that the establishments need to convey the heaviness of the dam. Different sort of establishments by and large experienced areSolid shake establishments, for example, stone have solid bearing force and relatively every sort of dam can be based on such establishments.

Rock establishments are reasonable for earthen and shake fill dams.

Residue and fine sand establishments recommend development of earth dams or low gravity dams.

Dirt establishments are probably going to cause gigantic settlement of the dam. Developments of gravity dams or shake fill dams are not reasonable on such establishments. Earthen dams after unique medicines can be manufactured.

Accessibility of Materials 

Accessibility of materials is another imperative factor in choosing the kind of dam. So as to accomplish economy in dam development, the materials required must be accessible locally or at short separations from the development site.

Spillway Size and Location 

spillway arranges the surplus waterway release. The limit of the spillway will rely upon the size of the surges to be by-passed. The spillway is hence substantially more imperative on waterways and streams with extensive surge potential.

Seismic tremor Zone 

On the off chance that dam is arranged in a tremor zone, its plan must incorporate seismic tremor powers. The kind of structure most appropriate to oppose seismic tremor stuns without peril are earthen dams and solid gravity dams.

Tallness of Dam 

Earthen dams are normally not accommodated statures in excess of 30 m or something like that. For more prominent statures, gravity dams are by and large favored.